GENERAL type
POWER RELAY : KSP-402 |
|
|
|
|
- KSP-402
-
|
- Shape / Dimension drawing
-
|
Rating volatage(v)
|
Rating
current (mA) |
Coil
resistance (Ω) |
Operation voltage(V) |
Return voltage(V) |
Max.
allowable voltage(V) |
AC |
24 |
410 |
17 |
|
above 30% |
110% |
110 |
96 |
320 |
220 |
48 |
1,200 |
DC |
12 |
210 |
51 |
above 10% |
24 |
105 |
200 |
48 |
50 |
1,150 |
110 |
26.5 |
3,900 |
Item / Load |
Resistive load (cos∮ = 1)
|
Inductive load (cos∮ = 0.4 L/R =
7ms) |
Rated load |
AC 110V, 30A DC 24V, 15A
|
AC 110V, 20A DC 24V, 7.5A
|
Carry current |
30A |
Max.switching capacity
|
AC 500VA, DC 250V |
Max.switching current
|
30A
|
Item |
Performance |
Contact resistance |
below 50mΩ
(initial value) |
Insulation resistance |
above
100MΩ(DC 500V Meg) |
Withstand voltage |
between
contacts : AC 1000V / 1min between
charging part : AC 1500V / 1min and
non - charging part : AC 1500V /
1min |
Lift time |
mechanical :
above 3,000,000 times electrical :
above 500,000 times |
Power consumption |
for AC :
about 9.6VA |
for DC :
about 2.5W |
Operating time |
below
50ms |
Return time |
below
50ms |
Withstand vibration |
10~55Hz
double amplitude 1.5mm |
Withstand impact |
80G |
Max. switching
frequency |
mechanical :
20times / min electrical : 20times /
min |
Ambient temperature |
-5℃
+40℃ |
Weight |
about
270g | |
|