KDFS-2000 | KDFH-E3 |                                                                                     TOP

 GENERAL type FLOATLESS SWITCH : KDFS-8PC


    KDFS-8PC                                                                                   

    Features                                                                                      



- Use when toneed control of liquid surface Multi-Purpose for purifying water to be   used for agficulture. sewage and dirty water treaments.

 

- Easy to install due to small in size and light in weight.

 

- Voltge of electrode(2 voltage) is operated by AC 12V.

    Performance Summary
Item
DFS-8PC
Rating voltage
  AC 100V, AC 220V
Voltage varlation range
  AC 110V/220C 50/60Hz ±10% within
Voltage between electrodes
  AC 12V (2nd voltage)
Power consumption
  about3.2VA
Operating resistance
  about 4KΩ
Return resistance
  about below 15KΩ
Response time
  In operating below 80ms, In return below 160ms
Ambient temperature
  -10 ~ +50℃
Insulation resistance
  below 100MΩ (at DC500V Meg)
Max. sense distance
  below 1km
Relay output contact capacity
  Ac 250V 2.5A, Ac 110V 5A (Resistive load)
Relay lifetime
  Electrical : above 500,000 times
  Mechanical : above 5,000,000 times
     
 
※ Please be sure E3 terminal to be earthed

※ Please be sure E3 terminal to be earthed


    KDFS-8PC (56) Wifing Diagram
Using example in water supply Using example in water drainage

 - Conevt to designated terminal after    checking in-put electricity.
 - After distributing wires, plese check up    wiring before using in-put electricity.


 

 - If the surface of water reach E1. motor    pump starts to work automatically, and    reach below E2 Motor pump stop    automaticlly.
 - While motor is workin, lamp is on.
 - A naugty spinning does notoccur, when the    level height is over pump level.
 

    KDFS-8PC (27) Wifing Diagram
Using example in water supply Using example in water drainage

 - Conevt to designated terminal after    checking in-put electricity.
 - After distributing wires, plese check up    wiring before using in-put electricity.


 

 - If the surface of water reach E1. motor    pump starts to work automatically, and    reach below E2 Motor pump stop    automaticlly.
 - While motor is workin, lamp is on.
 - A naugty spinning does notoccur, when the    level height is over pump level.
 

    Caution in Use                                                                            

 

- After checking up power source, ansd then connect to designated termainal.

 

- Please clean up electrode every six months.

 

- Electrode may be mal-functioning, if disconnection membrane is formed.

 

- Sensing distance is accurate by enploying fixing pad electrode.

 

- Do not use over-load above standartd at contacting point of out-put relay.

 

- Mal-function may occur when in-put voltage is over standard voltage.

 

- After finishing distributing wires, Please check up wires before using in-put   electricity.

 

- Do not use water containing oil.